Model Number: SSI 506 CBIE
Standard Number: IEC 60811-1-4
Cracks and deformation occur when the material is bend or wound under cold conditions. The apparatus is deigned to wound the cable samples on standardized mandrels under cold conditions.
|
The Cable is wound on the mandrel and frozen over a pre-determined time. The sample is then taken out and checked for visible cracks, discoloration or any other deformity due to cold temperature. The test is applicable for specimen of diameter up to and including 12.5 mm, above which the test is considered impracticable.
The Instruments conisit of
Metal Mandrel.
Metal Frame for mandrel attachment
.